ESA Series
+
  • ESA Series

  • Ultra-low noise design (<35 dB) 
  • Stacked design with flexible capacity expansion compatible with both new and old batteries 
  • Millisecond-level seamless switching ( <4ms) 
  • Supports DC arc protection 
  • Charging/discharging at 1 C at-20°C stable operation 
  • One-click upgrade with  one-click configuration 

 

Technical parameter

GW5K-ETA-G20

GW6K-ETA-G20

GW8K-ETA-G20

GW10K-ETA-G20

GW12K-ETA-G20

GW15K-ETA-G20

GW20K-ETA-G20

GW25K-ETA-G20

GW30K-ETA-G20

Battery Input Parameters

Battery Type

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Lithium iron phosphate (LIFEPO₄)

Rated voltage (V)

750

750

750

750

750

750

750

750

750

Voltage range (V)

700~950

700~950

700~950

700~950

700~950

700~950

700~950

700~950

700~950

Starting voltage (V)

720

720

720

720

720

720

720

720

720

Maximum Continuous Charging Current (A)

6.7

8.1

10.7

13.4

16.1

20.1

26.7

33.3

40.0

Maximum continuous discharge current (A)

7.4

8.9

11.8

14.7

17.7

22.1

29.4

36.7

44.1

Maximum Charging Power (KW)

5

6

8

10

12

15

20

25

30

Maximum Discharge Power (KW)

5.5

6.6

8.8

11

13.2

16.5

22

27.5

33

Photovoltaic Input Parameters

Maximum Input Power (KW)

10

12

16

20

24

30

40

50

60

Maximum input voltage (V) *1

1000

1000

1000

1000

1000

1000

1000

1000

1000

MPPT Voltage Range (V) *2

120~950

120~950

120~950

120~950

120~950

120~950

120~950

120~950

120~950

Starting voltage (V)

150

150

150

150

150

150

150

150

150

Rated input voltage (V)

750

750

750

750

750

750

750

750

750

Maximum MPPT input current (A)

21/21/21

21/21/21

21/21/21

21/21/21/21

21/21/21/21

21/21/21/21

21/21/21/21

21/21/42/42

21/21/42/42

Maximum short-circuit current of MPPT (A)

26/26/26

26/26/26

26/26/26

26/26/26/26

26/26/26/26

26/26/26/26

26/26/26/26

26/26/52/52

26/26/52/52

MPPT quantity

3

3

3

4

4

4

4

4

4

Number of strings per MPPT input channel

1/1/1

1/1/1

1/1/1

1/1/1/1

1/1/1/1

1/1/1/1

1/1/1/1

1/1/2/2

1/1/2/2

Grid-connected output parameters

Power rating (KW)

5

6

8

10

12

15

20

25

30

Rated output apparent power (KVA)

5

6

8

10

12

15

20

25

30

Rated input apparent power (KVA)

5

6

8

10

12

15

20

25

30

Maximum output apparent power (KVA) *3

5

6

8

10

12

15

20

25

30

Maximum Input Apparent Power (KVA)

43.5*4

43.5*4

43.5*4

43.5*4

43.5*4

43.5*4

43.5*4

55.2*5

55.2*5

Rated voltage (V)

220/380, 230/400, 3L/N/PE

Voltage range (V)

180~260

180~260

180~260

180~260

180~260

180~260

180~260

180~260

180~260

Rated frequency (Hz)

50

50

50

50

50

50

50

50

50

Maximum Output Current (A) *4 (@380V)

7.6

9.1

12.2

15.2

18.2

22.8

30.4

37.9

45.5

Maximum Output Current (A) *4 (@400V)

7.3

8.7

11.6

14.5

17.4

21.8

29.0

29.0

43.5

Maximum input current (A) *4

63.0*4

63.0*4

63.0*4

63.0*4

63.0*4

63.0*4

63.0*4

80.0*4

80.0*4

Total current waveform distortion rate

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

Off-grid output parameters

Rated apparent power (KVA)

5

6

8

10

12

15

20

25

30

Maximum Apparent Power (KVA) *5 — Off-grid

5.5 (10.0, 10s)

6.6 (12, 10s)

8.8 (16.0, 10s)

11 (20.0, 10s)

13.2 (24, 10s)

16.5 (30, 10s)

22 (30.0, 10s)

27.5 (45.0, 10s)

33 (45.0, 10s)

Maximum Apparent Power (KVA) *5 — Grid connection

43.5

43.5

43.5

43.5

43.5

43.5

43.5

55.2

55.2

Rated voltage (V)

220/380, 230/400, 3L/N/PE

Rated Frequency (Hz)

50

50

50

50

50

50

50

50

50

Maximum Current (A) *5

11.4

13.7

18.2

22.8

27.3

33.4

33.4

50

50

Power factor

~1 (adjustable from 0.8 to 0.8 lag)

Total Voltage Waveform Distortion Rate (@Linear Load)

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

<3%

Productiveness

Maximal efficiency

98.00%

98.00%

98.00%

98.10%

98.10%

98.10%

98.10%

98.20%

98.20%

European Efficiency

96.40%

96.90%

97.10%

97.20%

97.20%

97.30%

97.30%

97.40%

97.40%

Maximum efficiency on the battery side ↔ AC side

98.00%

98.00%

98.00%

98.00%

98.00%

98.00%

98.00%

98.00%

98.00%

Protect

String Current Monitoring

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Insulation impedance testing

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Residual current monitoring

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Input Reverse Protection

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Battery Reverse Connection Protection

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Island Protection Against Voltage Surges

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Overcurrent Protection

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

AC Short-Circuit Protection

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Overvoltage Protection

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

DC Switch

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Ensemble

Direct Street Flood Protection

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

Level 2 (Optionally Level 1)

AC Surge Protection

Secondary

Secondary

Secondary

Secondary

Secondary

Secondary

Secondary

Secondary

Secondary

DC Arc Protection

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Essential parameter

Working Temperature Range (°C)

-35~+60

-35~+60

-35~+60

-35~+60

-35~+60

-35~+60

-35~+60

-35~+60

-35~+60

Relative humidity

0~100%

0~100%

0~100%

0~100%

0~100%

0~100%

0~100%

0~100%

0~100%

Maximum working altitude (m)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

4000 (load reduced from >2000)

Cooling-down method

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Smart Air Cooling

Human-computer interaction

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

LED, WLAN+APP

Communication Method (BMS)

CAN

CAN

CAN

CAN

CAN

CAN

CAN

CAN

CAN

Communication mode

RS485, WIFI+LAN+Bluetooth; optional 4G+Bluetooth

Weight (Kg)

34.0

34.0

34.0

34.0

34.0

34.0

34.0

34.0

34.0

Size (Width × Height × Thickness, mm)

800×340×270

800×340×270

800×340×270

800×340×270

800×340×270

800×340×270

800×340×270

800×340×270

800×340×270

Noise (dB)

≤35

≤35

≤35

≤40

≤40

≤40

≤40

≤45

≤45

Levels of protection

IP66

IP66

IP66

IP66

IP66

IP66

IP66

IP66

IP66

Way to install

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Wall-mounted/Landing

Attestation

Grid Connection Standards

IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 62920, CISPR 11, EN 55011, AS/NZS 61000.6.3/.4, AS 61000.6.4

Safety Standards

IEC62109-1/-2, IEC 63037

EMC

IEC/EN 61000-6-1/-2/-3/-4

 

keywords:

ESA Series

Product inquiry

Note: Please leave your phone number or email address, and our professionals will contact you as soon as possible!